Lines running in two directions are not yet a coordinate reference

Three things have to be on the drawing before a two-axis plate can be quoted: the angle between the grating vectors, the datum that angle is measured from, and the mark that fixes which way round the plate is.

By

A magnetic linear encoder readhead shown as a two-axis reading arrangement, standing for the reader a planar glass scale is specified against

The short answer

Everything normally checked on an encoder scale — period, line width, duty cycle, optical contrast — describes one axis at a time. None of those checks can see that the two axes are not at 90°. That angle is the difference between a pair of gratings that share a substrate and a coordinate reference a stage can close its loop around.

It is also not a small correction. One arcsecond of orthogonality error displaces the other axis by 0.97 µm over a 200 mm span. 0.01° displaces it by 34.9 µm. Over the same span and the same angle, the reading along the axis shortens by 3.0 nm. The error therefore survives every single-axis measurement and appears only when X and Y are compared — which is the one comparison a pitch check does not make.

What a two-axis plate is, and what it is not

A crossed grating is a pattern with two periodic directions on one substrate. It becomes a 2D encoder scale when a reader can separate those two directions into independent X and Y signals. TL OPTIK supplies the patterned glass; the separation is done by the readhead, and the two halves of that pair have to be specified together. The moiré grating family is the neighbouring case, where a measuring grating works against a scanning grating rather than against a readhead's own optics.

Three other products are often compared with this one, and the drawing consequences differ:

  • Transmissive and reflective linear scales carry one axis. Two of them can be mounted square to each other, and then the squareness of the machine — not of the part — sets the axis relationship. A single planar plate moves that relationship into the component, where it can be written down and inspected.
  • Crossed-scale reticles also carry two directions, but they are read by eye through a microscope and are calibrated against a stage micrometer. Their XY geometry is a visual reference, not an encoder track.
  • A camera calibration target has a grid too. A grid and an encoder scale are not interchangeable: one supplies a positional reference to a reader, the other supplies known features for estimating camera geometry.

Four quantities, and the one that is usually missing

A two-axis scale drawing has to settle four things. The published product family states all four as drawing inputs rather than house values, which is honest but puts the whole burden on the drawing:

  • X and Y pitch. pX and pY are specified independently; equal pitch is not assumed.
  • Line width and duty convention, per axis. Including whether duty refers to the opaque or the clear portion.
  • Orthogonality and placement. The X/Y angle, the coordinate origin, and the pattern's position relative to the mounting datums.
  • Active area and references. Patterned width and height, edge exclusions, reference marks and their coordinates.

The first two are measured on one axis at a time, with a microscope and a threshold, and they are what most incoming inspection actually does. The fourth is a placement question and is covered by the general pattern-to-edge and marking discussion. The third is the one that has no single-axis test: an angle between two directions cannot be seen while looking at either direction on its own.

What orthogonality means on a crossed grating

Two grating vectors describe the pattern. gX is perpendicular to the X lines and points along the direction in which the X pitch repeats; gY does the same for the Y lines. On an ideal plate the angle between them is exactly 90°. Orthogonality is the departure from that, written here as δ, and it is a property of the pattern's placement, not of the line width.

A plate with a dashed nominal right-angle frame and two solid blue grating vectors, gX and gY, rotated away from it by an exaggerated angle delta, with a dimension showing the cross-axis offset at the far end of the X vector and a ladder converting 1 arcsec, 10 arcsec, 0.01 degree and 1 arcmin into micrometres over 200 millimetres.
δ is measured between the grating vectors, not between the plate edges. The angle is drawn at 6.5° so that it can be seen; the ladder underneath converts the angles a drawing actually uses into a cross-axis error over 200 mm.

What the angle does to a reading follows directly. Moving a distance L along gX, a reader aligned to the plate sees a displacement of L · sin δ in the Y direction, and a shortening of L · (1 − cos δ) in the X reading. The first is the cross-axis error; the second is the along-axis error. At the angles a drawing uses, the first is enormous compared with the second, which is why an orthogonality problem behaves like a squareness problem and not like an accuracy problem.

From a budget to a number on the drawing

The useful direction of the calculation is backwards. A stage designer knows how much cross-axis error the loop can absorb; dividing that by the travel over which it applies gives the angle. The table below does it for three allowances and three spans.

Table 1 — the orthogonality a cross-axis budget allows
Cross-axis allowanceover 100 mmover 200 mmover 300 mm
2 µm4.1 arcsec2.1 arcsec1.4 arcsec
5 µm10.3 arcsec5.2 arcsec3.4 arcsec
10 µm20.6 arcsec10.3 arcsec6.9 arcsec

δ = allowance ÷ span, converted at 1 arcsec = 4.848 µrad. Arithmetic on the allowance and the span, not a supplier tolerance. The allowance includes machine squareness and reader mounting: it is the whole budget, not the plate's share of it.

Read it in the direction you actually have. If the stage can absorb 5 µm of cross-axis error over 200 mm of travel, the plate has to be within 5.2 arcsec — and that is the entire allowance, before machine squareness and reader mounting are paid for. A plate at 5 arcsec on a machine at 10 arcsec gives 15 arcsec worst case, or 11.2 arcsec if the two are treated as independent and combined by root-sum-square. Neither number is the plate's fault alone, and that is the reason the drawing should state the plate's share rather than a system total that it cannot control.

The same angle at a different travel

Because the cross-axis error is proportional to travel, an orthogonality figure means nothing without the span it applies to. A plate at 0.01° is comfortable on a 20 mm stage and unusable on a 300 mm one — the same plate, the same drawing, two different verdicts.

Log-log chart of cross-axis error in micrometres against travel from 10 to 1000 millimetres, with four parallel lines for 1, 10, 36 and 300 arcsec, a shaded 2 to 5 micrometre budget band, and a marker at 200 millimetres on the 36 arcsec line where the error is 34.9 micrometres.
Each line is one orthogonality value; the vertical distance between them is the angle. A 5 µm cross-axis budget survives only 28.6 mm of travel at 36 arcsec, and the full metre at 1 arcsec.

Two consequences follow that are worth carrying into a specification. The first is that the allowable angle should be quoted against the longest travel the stage will use, not against the plate diagonal and not against a nominal figure such as "90° ± 1′". The second is that a part can pass a short-travel evaluation and fail on the machine, which is a disagreement about the span rather than about the plate.

The same angle measured along the axis

The along-axis term is the one that makes orthogonality hard to catch. It is second order in the angle, and it is smaller than the cross-axis term by a factor of roughly 2/δ, with δ in radians.

Log-log chart over 300 millimetres of travel with two curves against orthogonality from 1 to 1000 arcsec: the cross-axis error rising to 872 micrometres and the along-axis error staying below 1 micrometre until 532 arcsec. At 36 arcsec the two read 52.4 micrometres and 4.6 nanometres, a ratio of about 11,500.
Both curves use the same angle and the same 300 mm span, so the vertical gap between them is the ratio of the two effects. An angle that destroys a cross-axis budget is still invisible in the reading along the axis.

At 36 arcsec the cross-axis error over 300 mm is 52.4 µm and the along-axis shortness is 4.6 nm — a ratio of about 11,500. To lose a whole micrometre along the axis over 300 mm you would need 8.9 arcmin, or 532 arcsec, and by then the cross-axis error is 774 µm. This is why a report that shows pitch and line width "in tolerance" says nothing whatever about orthogonality.

Walk-off, which usually bites first

There is a third consequence, mechanical rather than metrological. If the plate is rotated relative to the machine and the readhead cannot follow, the sensing spot drifts sideways across the grating by the same L · sin δ. The travel ends when the spot reaches the edge of the reader's usable window, not when the accuracy fails. With a ±0.5 mm window, 36 arcsec allows about 2.9 m of travel, 1 arcmin allows 1.72 m and 0.1° allows 286 mm. On a long axis this is often the requirement that decides the purchase, and it is worth stating the window in the RFQ for that reason alone.

Which datum can carry the angle

An angle needs two references to be measured against, and a plate offers four candidates. They differ by more than five orders of magnitude, which is enough to decide the question before any discussion of capability.

Table 2 — candidate references, converted to an equivalent angle over 200 mm
ReferenceWhere the limit comes fromIts own limitEquivalent angleCross-axis at 200 mm
Pattern marks, one passWriter address grid12.5 nm0.013 arcsec0.0125 µm
Mark on a second layerSecond-layer alignment, 3σ225 nm0.23 arcsec0.23 µm
Machined bore or centreConcentricity, Ø tolerance0.02 mm10.3 arcsec10 µm
Cut outlineOutline cutting accuracy±0.02 mm20.6 arcsec20 µm
Ground edgeEdge squareness, 0.015 in per 1 in0.86°3,094 arcsec3.0 mm

Angles are the stated linear limit divided by 200 mm; the cross-axis column converts that angle back over the same span. Values on the left are published capability figures; the conversions are arithmetic. The pattern-mark rows are floors set by the equipment, not guaranteed placements — the achieved value is what the inspection measures.

The conclusion is blunt: only pattern-internal marks can carry a requirement of a few arcseconds. The machined bore and the cut outline can carry something like 10 to 20 µm at 200 mm — fine for the position of the pattern inside the part, useless as an angle reference. The ground edge cannot carry anything at all at that span, and that is not a criticism of the blank specification: an edge is a handling and seating feature, and the published 0.015 in per 1 in is a perfectly reasonable value for what it is for.

Two practical rules come out of the table. The angle should be measured between two pattern features as far apart as the active area allows, and the drawing should say so explicitly, because a default inspection will measure whatever is convenient. And where a bore is the mounting datum — the usual arrangement on a round encoder disc — the drawing should still say that the bore locates the part mechanically and that the angle is measured on the pattern.

One exposure or two

Where both gratings are written in a single pass, the angle between them comes from the writer's stage frame, and it is not affected by how the plate was fixtured for cutting. Where a second layer is involved — an origin mark written separately, a second exposure, or a pattern added after a first process — the published second-layer alignment of 225, 225 and 350 nm at 3σ for the three configurations becomes the relevant number, and it converts to 0.23 arcsec over 200 mm.

What either route can actually hold is not something this page can state. What the numbers do show is that the writer is not the limit: over 200 mm the address grid corresponds to 0.013 arcsec and the second-layer alignment to 0.23 arcsec, both far below any requirement a stage would write. Which route a given artwork takes is a manufacturing decision reviewed with the pattern data, so the useful thing for a customer to state is the requirement and the span, and to ask for the route to be confirmed in the quotation rather than assumed.

The origin mark: two separate jobs

A reference mark on a planar scale is asked to do two things that are usually collapsed into one line on a drawing, and each has its own arithmetic.

The first job is to be findable. The mark is only wholly visible while it sits inside the reader's window, so its width has to exceed the window by enough to be captured with both edges. The mark is at least partly visible over a centre travel of m + W and wholly visible over m − W. A mark narrower than the window never appears whole, and the reference degrades into an edge.

Top: three panels showing a one millimetre reader window at three positions relative to a three millimetre dark origin mark, with the resulting visible spans of four and two millimetres. Bottom: four small plates with the same off-centre asymmetric mark under four installations, showing X and Y directions plus-plus, minus-plus, minus-minus and plus-minus.
Top: the mark has to be wider than the window before both of its edges can be located. Bottom: the same mark under four installations — a plate turned over, rotated, or both inverts one or both axes, and only an off-centre mark distinguishes them.
Table 3 — mark size against window size
Mark mWindow WWholly visible overPartly visible over
1 mm1 mm0 mm2 mm
3 mm1 mm2 mm4 mm
3 mm2 mm1 mm5 mm
5 mm1 mm4 mm6 mm

m − W and m + W of reader centre travel. The window value is a property of the reader, not of the plate; the mark size is a drawing field. No mark size is published for this product, because it follows from the reader rather than from the glass.

The second job is to fix which way round the plate is. A plate can be installed as drawn, turned over, rotated by 180°, or both, and those four cases map the coordinates to (+X, +Y), (−X, +Y), (−X, −Y) and (+X, −Y). A mark placed on either centre line maps onto itself under at least one of those transforms, so two installations become indistinguishable. A mark placed off both centre lines lands in a different quadrant each time, and one reading resolves the question.

The cost of getting this wrong is not a tolerance. It is the plate dimension: up to 228.6 mm on a 9 in format, presented as a valid coordinate. The film side and the viewing direction belong on the drawing next to the mark's coordinates, and a mirrored coordinate set is one of the few errors that is cheaper to prevent than to detect.

What is published, and what has to be agreed

The numbers in this section are the published reference capabilities of the direct-write configurations and of the substrate range. They describe what the equipment and the glass can hold. They do not define an orthogonality value for a delivered plate, and this page does not add one.

Table 4 — published writer reference values, three configurations
ParameterConfiguration IConfiguration IIConfiguration III
Minimum feature0.75 µm0.75 µm1 µm
Minimum line and space1.5 µm1.5 µm2 µm
Address grid12.5 nm12.5 nm25 nm
Edge roughness, 3σ30 nm40 nm50 nm
CD uniformity, 3σ55 nm65 nm75 nm
Stitching stability, 3σ30 nm60 nm70 nm
Second-layer alignment, 3σ225 nm225 nm350 nm

From the laser direct writing capability page, November 2026. These are equipment reference values used to choose a writing route. They are not a product guarantee, and none of them is a statement about the angle between two gratings. The page publishes maximum exposure fields of 205 × 205 mm and 410 × 410 mm but does not map a field size to a configuration, so no mapping is inferred here.

Table 5 — published substrate range
PropertyPublished value
Square formats3 / 4 / 6 / 7 / 8 / 9 in
Thickness≥ 0.3 mm; writer accepts 0–12 mm
Total thickness variation≤ 2 µm
Flatness≤ 2 µm over the agreed area
Encoder glass substratesmaximum diameter 1500 mm, minimum annular width 5 mm, thickness ≥ 0.4 mm, surface figure λ/4, concentricity ≤ 0.02 mm
Edge preparationground edges with a 45° chamfer; squareness < 0.015 in per 1 in; |A − B| < 5 µm
Cuttingreference kerf ≤ 0.02 mm

From the precision glass preparation and UV laser cutting capability pages, November 2026. Material options and coating are reviewed per drawing.

Not published, and therefore not claimed here. No orthogonality tolerance, no origin-mark size, no pitch catalogue, no accumulated-interval specification and no default sampling plan for the angle. Lead time, price, minimum quantity and yield are quoted per project and are not stated on this page. Where a question cannot be answered from a drawing and a stated application, the answer is a review, not a number.

Industry reference only. This does not represent a confirmed TL OPTIK capability or a guaranteed supplier specification. Final requirements must be reviewed and agreed in writing.

What moves a drawing into review

Four drawing decisions move a two-axis scale from straightforward to a review, and all four are visible before any manufacturing starts:

  • Pitch ratio. Equal pitches and pitches related by a simple ratio are the easy cases. Unrelated pitches are not a problem in themselves, but the pattern data and the reading geometry have to be reviewed together, because the two gratings then diffract differently.
  • Active area against outline. The usable two-dimensional field is smaller than the patterned area, which is smaller than the plate. Edge exclusion, the reader footprint and any clamping zone all come out of the travelling region, so a drawing that quotes the outline as the stroke overstates the travel.
  • Thickness and flatness. A plate that is clamped flat at use and free at inspection is measured in a different state from the one it works in. The evaluation area, the support and the reference temperature belong on the drawing, not in a covering note.
  • Inspection scope. Line width, pitch, orthogonality and defects are four different measurements. A quotation that covers one of them is not a quotation for the other three, and the difference shows up at acceptance rather than at order.

What to send with an enquiry

To quote

  • Artwork with revision and declared units
  • pX and pY, each with its tolerance
  • Line width and duty convention per axis
  • Orthogonality, with the span it applies to and the datum it is measured from
  • Active area, edge exclusion and overall outline
  • Thickness, material and film side
  • Optical mode, wavelength and working gap
  • Origin and reference mark geometry, with coordinates
  • Quantity and required inspection scope

To accept the part

  • Which method measures the angle, and over what baseline
  • Reference temperature and support during measurement
  • Sampling positions for pitch and line width
  • Defect limits by zone, not a single global count
  • Whether the film side is stated on the report
  • Which drawing revision the report refers to
  • Whether the reader test is the customer's or the supplier's
  • What happens to a part that fails one of the four measurements

How the angle is inspected

The measurement itself is simple in principle. Locate the same feature pattern on both axes at two widely separated stations, and divide the change in cross-axis position by the baseline: δ = (Δy₂ − Δy₁) ÷ L. The result is only as good as the baseline and the stability, which is why the two numbers that matter on the inspection plan are the span and the temperature.

The equipment is not the limit. A 12.5 nm address grid over 200 mm corresponds to 0.013 arcsec, two orders below the requirement anyone is likely to write. What limits the measurement is the baseline, the support, the temperature and the repeatability of locating the same feature twice.

Two things are worth writing down rather than leaving to habit. First, the angle should be reported with its baseline, since the same plate measured over 50 mm and over 200 mm produces two different numbers from the same deviation. Second, the acceptance criterion should name the drawing revision, because an angle requirement without a revision is a requirement that can be moved after the fact.

On acceptance. The limits that govern a delivered plate are the ones on the approved drawing, the purchase order or the quality agreement between the two parties. This page offers a method and a set of arithmetic conversions; it does not create tolerances, and nothing here should be read as a quality guarantee for an unquoted part.

Questions that come up before an order

Is a crossed grating the same as a 2D encoder scale?

No. A crossed grating is a pattern with two periodic directions. A 2D encoder scale is that pattern plus a reader that separates the two directions into X and Y. The glass can be made to any two pitches; whether the pair works as a coordinate reference also depends on the angle between the gratings, the origin, and the reader's optical arrangement.

Can the two axes use different pitches?

Yes. pX and pY are specified independently, and neither the duty cycle nor the line width has to match. Both need their own tolerance and their own duty convention, and the pattern data is reviewed against the complete artwork rather than as two separate scales — a reading architecture that works at a single 20 µm pitch does not automatically work when one axis is 20 µm and the other 40 µm.

What orthogonality value should the drawing state?

Start from the cross-axis error the stage can absorb and divide it by the travel over which that error applies. A 5 µm allowance over 200 mm is 25 µrad, or 5.2 arcsec — and that allowance also has to cover machine squareness and reader mounting, so the plate's share is smaller still. An angle written without the span it applies to cannot be inspected, because the same plate produces different errors over different travels.

Can the plate edge be used as the angle reference?

Not for a scale. The published blank-edge squareness is 0.015 in per 1 in, which is 0.86°; over 200 mm that is 3.0 mm of cross-axis error. The cut outline is closer — about 20 µm at the same span — but still an order of magnitude away from a scale requirement. The reference has to be pattern marks, positioned and agreed on the drawing.

Does the origin mark make the scale absolute?

No. A single reference mark gives one known position. It removes the need to home on power-up and it fixes the coordinate frame, but it does not identify position anywhere else on the plate. Absolute position needs a code laid out across the full area, which is a different artwork, a different reader and a separate review.

How is the angle inspected, and can I get a report?

The angle is measured over the longest baseline the active area allows, between pattern features on both axes, at a stated temperature and support. The report should carry the baseline, because the value is meaningless without it, and the drawing revision it refers to. Which measurements are included is part of the quotation — line width, pitch, angle and defects are four separate inspections and they are not interchangeable.

Send the artwork and the two angles

The useful enquiry for a two-axis scale carries the pattern, the two pitches, the orthogonality with its span, and the origin mark in relation to the datums. If the angle is still open, say what the stage can absorb and over what travel — that is enough to agree a number.

Sources and scope

The published values below are the only numbers this page takes as given. Every converted figure — the arcsecond-to-micrometre ladder, the budget table, the equivalent angles, the mark-and-window spans and the ratios in the figures — is arithmetic on a stated input, printed next to it. Angle conversion uses 1 arcsec = 4.848 µrad. None of these conversions is a TL OPTIK tolerance, and none of them describes a delivered part without a drawing.

Product and process references

A note on the numbers. Published product and capability pages read on 9 November 2026: 2D glass encoder scales, moiré gratings, transmissive and reflective glass encoder scales, crossed-scale reticles, incremental encoder discs, laser direct writing, precision glass preparation and UV laser cutting. Every other figure is arithmetic performed on those values, stated as such.

Industry reference only. This does not represent a confirmed TL OPTIK capability or a guaranteed supplier specification. Final requirements must be reviewed and agreed in writing.

Search