JGS-1, JGS-2 or JGS-3?
Compare quartz glass grades by working wavelength, finished thickness and surface condition, then define the inspection requirement.
By TL OPTIK

Choosing a quartz glass grade starts with the light that must pass through the finished part. Specify the operating wavelength, substrate thickness and surface condition before comparing reference curves or requesting a quotation.
Choose by the optical requirement
| Starting grade | When to evaluate it | What to verify |
|---|---|---|
| JGS-1 synthetic fused silica | Shorter-wavelength UV transmission is a priority. | Transmission at the required wavelength and thickness; fluorescence or laser-use requirements where relevant. |
| JGS-2 fused quartz | A UV-visible optical substrate is needed. | Actual material data at the operating wavelength; do not assume it is interchangeable with a synthetic UV grade. |
| JGS-3 low-OH fused quartz | Reducing hydroxyl-related infrared absorption is important. | Residual absorption and transmission near the long-wavelength cutoff, using the intended finished thickness. |
These are starting points for evaluation. A grade name alone does not specify the complete optical performance of a finished component. The drawing, material data and agreed inspection conditions complete the specification.
Compare like-for-like transmission data
Two curves can look different even when both samples carry the same grade designation. Check whether they describe the same thickness, surface condition and measurement definition.
Internal transmittance describes transmission through the material with surface-reflection effects excluded or corrected according to the measurement method. Total transmittance also includes the effects of the entry and exit surfaces. An uncoated plate and an antireflection-coated plate therefore should not be compared as though their surface losses were identical.
The finished thickness also matters. A longer path through an absorbing material can reduce transmission at the wavelength of interest. Use data for the proposed thickness or obtain an agreed evaluation; do not copy a value from a thinner sample into the finished-part specification.
When comparing curves, record:
- Material grade and the sample or batch identification, where available.
- Sample thickness and whether the surfaces are polished, coated or patterned.
- The wavelength scale, including any broken or nonuniform axis.
- Whether the value is internal or total transmittance.
- The measurement method and the wavelengths used for acceptance.
A curve without these conditions can help screen materials. It cannot by itself certify the performance of the ordered part.
Check absorption where the instrument operates
Hydroxyl-related absorption is one reason to distinguish an infrared-oriented quartz grade from a UV-oriented grade. A low-OH grade can be useful when that absorption overlaps the instrument's working band. It does not remove every absorption feature or guarantee high transmission up to a reference range's endpoint.
For a narrowband instrument, agree the transmission requirement at its operating wavelength. For an instrument using several wavelengths or a continuous band, state all required wavelengths or the band and the minimum acceptable transmission. Passing at one wavelength does not demonstrate performance across the whole band.
For deep-UV exposure, begin with the relevant UV material data. Do not select an infrared grade from a broad reference range that happens to include a UV wavelength. Laser applications also require the operating mode, fluence or power density, surface condition, coating and any specified damage-threshold requirement to be reviewed.
Define the part after material selection
The glass grade and the finished component solve different parts of the problem. After selecting a material candidate, define the outline, thickness, clear aperture and surface requirements around the assembly and optical path.
A bare polished substrate, a coated blank and a patterned component are different delivery states. For a patterned component, identify the clear and opaque regions, coating requirements, pattern polarity and alignment datums. A transparent opening in the coating still contains glass unless a physical hole is specified.
TL OPTIK performs glass cutting, double-side polishing, coating, photoresist coating, exposure, development and etching, and inspection in-house. The applicable coating design, dimensions and inspection requirements are reviewed for the individual project; the process list is not a universal tolerance or optical-performance guarantee.
For the mechanical and surface specification, see Fused Silica Substrates: Geometry, Flatness and Inspection. For the broader relationship between glass and coating functions, see Choosing Glass Substrates and Optical Coatings.
Make the acceptance requirement explicit
A useful drawing or inquiry states the material candidate, finished thickness, working wavelength and required transmission together. Add the surface or coating state and whether the requirement applies to internal or total transmittance. Define the inspected area and the required record, such as material documentation or an agreed finished-part inspection report.
For an initial discussion, send:
- The working wavelength or wavelength band and the component's role.
- The preferred JGS grade, or a request to compare suitable candidates.
- The outline, thickness, clear aperture and relevant drawing revision.
- The polished, coated or patterned delivery state.
- The optical acceptance conditions, quantity and records needed.
If some conditions are not yet fixed, identify them as open items. A preliminary engineering review can then separate what is already specified from what must be agreed before manufacture.
Questions that affect the comparison
Can I compare two suppliers' curves directly?
Only after checking that thickness, surface condition, wavelength scale and the transmittance definition are comparable. If those conditions differ or are missing, use the curves for initial screening and request comparable data before setting an acceptance limit.
Is one transmission value enough for a multiwavelength instrument?
It is enough only when the agreed requirement is limited to that wavelength. If the instrument uses several wavelengths or a band, specify those points or that band and the corresponding acceptance requirement.
Should acceptance be performed on the raw glass or the finished part?
The two checks answer different questions. Material documentation identifies the starting material; finished-part inspection addresses the ordered geometry, surface, coating and optical requirements. Agree which records are needed and where each requirement will be verified.
Discuss your optical substrate
Choose the corresponding JGS-1, JGS-2 or JGS-3 product page for supply specifications, or send your drawing and optical requirements.