Single crossline
A direct centre reference for projection, alignment and straightforward visual comparison.
Custom patterned glass reticles for collimators, visual autocollimators and optical alignment instruments, defined around the optical layout and mounting datums.
Instrument reticles
TL OPTIK manufactures drawing-defined glass reticles for projected references, visual receiving planes and replacement instrument assemblies. Pattern geometry, polarity and datum position are reviewed together so the finished component fits the intended optical and mechanical stack.
Choose this product when a crossline, ring, scale or custom reference must sit at a defined focal plane in a collimation or angle-measurement instrument. It is the patterned optical component, not a complete autocollimator, sensor or software system.

Define the component role first
In a collimator, the patterned reference is placed near the objective focal plane and projected as a parallel beam. A visual autocollimator observes the reflected return image in a receiving plane; depending on the design, this can include an eyepiece reference reticle. Camera-based instruments may replace that receiving reticle with a CCD or CMOS sensor.
For this reason, “autocollimator reticle” is not one universal drawing. State whether the requested part is the projected pattern, the visual receiving reference or a replacement component copied from an existing instrument.
Pattern selection
Pattern names alone are not enough. Line geometry, image sense and the relationship to the mating or return image must be defined for the assembled instrument.
A direct centre reference for projection, alignment and straightforward visual comparison.
A paired-line reference that can keep the return image visible between lines when matched to the instrument.
Circular references for centring, symmetry checks and alignment around an optical axis.
Linear or angular references designed around focal length, magnification and the instrument reading convention.
Directional and two-axis references for alignment, image position and comparative inspection.
Clear openings, targets, symbols or combined layouts manufactured from approved artwork.
Technical specifications
These fields establish the specification structure. Final values and tolerances follow the approved drawing and agreed inspection method.
Optical-path fit
The patterned surface must be located and oriented relative to the focal plane. In autocollimation, a reflecting surface returns the projected reference to the receiving plane. A small mirror tilt produces a larger optical deflection; for a simple small-angle arrangement, x ≈ 2fθ describes the geometry between focal length, angle and return-image displacement.
This relation is not a complete accuracy specification. Instrument alignment, mechanics, sensor or observer and calibration remain part of the final measurement result.
Concept only — final optical layout and scale definition follow the instrument design.
Instrument applications
Projected crosslines, apertures and alignment references used to establish an optical axis or compare component position.
Projected and receiving references for observing small angular changes from a reflected return image.
Custom references for checking tilt, alignment, squareness, parallelism or other system-level geometry.
TL OPTIK supplies the patterned glass reticle. The complete autocollimator, mechanical assembly, sensor, software and system calibration remain outside the component supply scope unless separately agreed.
Inquiry checklist
A replacement sample helps identify the construction, but a controlled drawing is still needed to define what will be inspected and accepted.
Acceptance should separate pattern geometry from installed instrument performance. Inspect line width and spacing, pattern centre, orientation, polarity, clear aperture and visual defects against the approved drawing. Complete angle accuracy also depends on focal length, optical alignment, mechanics, detector or observer and calibration; it is not defined by reticle tolerance alone.
Related engineering
Common questions
A collimator reticle is placed near the focal plane and projected as a reference at infinity. An autocollimator uses a projected reference and observes its reflected return image. A visual instrument may also use an eyepiece or receiving reticle, while an electronic instrument may place a camera sensor at the receiving plane. The required component role must therefore be identified on the drawing.
A single crossline provides a direct centre reference. A double crossline can create a clear comparison space for a mating or return image, but its line width and separation must suit the instrument magnification, illumination and expected image size.
A linear displacement in the receiving focal plane represents an angle through the instrument focal length and measurement geometry. In a simple small-angle autocollimation arrangement, return-image displacement is approximately x ≈ 2fθ. The scale therefore cannot be transferred between instruments without reviewing focal length and the reading convention.
Provide the existing component dimensions, mounting datums, patterned-side orientation, viewing direction, focal-plane location and clear images or measured artwork. A physical sample is useful, but the acceptance drawing should define the final geometry and orientation.
No. Reticle geometry is one contributor. Complete instrument accuracy also depends on focal length, optical alignment, mechanical stability, detector or observer, signal processing and calibration. These should be verified at instrument level.