Custom ChArUco Calibration Targets

Photolithographic chrome-on-glass ChArUco boards that combine a chessboard with unique ArUco markers for camera calibration when the plate is only partly in view.

Two chrome-on-glass ChArUco calibration plates on a neutral background, with a larger annotated plate behind a smaller plate

Chessboard corners with unique marker IDs

A ChArUco calibration target embeds uniquely coded ArUco markers in the white squares of a chessboard so software can identify checkerboard corners even when the plate is only partly in the camera field of view.

TL OPTIK manufactures the photolithographic chrome-on-glass component. Compatibility with OpenCV, HALCON or another workflow depends on the agreed dictionary, grid geometry and software settings, not on a generic certification. Specify square size, marker size, dictionary and substrate on the drawing.

These chrome-on-glass targets are patterned by photolithography and wet etching. Compare fabrication routes using measured corner geometry, pitch, flatness and contrast under the intended imaging conditions; the process name alone does not establish calibration accuracy.

Example shown: overall size 270 × 165 mm, 12 × 12 mm checkers and a 5 × 5 dictionary. Other sizes and dictionaries are made to drawing.

Why specify a photolithographic ChArUco target

A standard checkerboard can fail when the peripheral field of view is clipped, while standalone ArUco markers lack the sub-pixel corner intersection used in high-end metrology. The hybrid layout addresses both limits, provided the dictionary, geometry and detector match the finished plate.

Occlusion and partial-view identification

Each ArUco marker carries a unique binary ID. Dictionaries such as DICT_4X4, DICT_5X5, DICT_6X6, or a custom dictionary can be specified. When compatible software detects enough markers and corners, it can assign (X, Y) coordinates to the visible checkerboard intersections even if most of the plate is outside the field of view or hidden by a fixture. A 70% clipped or blocked field is an application example for the algorithm, not a guarantee of a complete camera-calibration system.

Saddle-point geometry, by process grade

Camera calibration depends on locating checkerboard corners. Specify corner geometry separately from centre-to-centre pitch and full-field placement. The table distinguishes standard production from master-mask grades; select the applicable route and inspection method instead of combining the limits into one blanket tolerance.

Low-reflective chrome under coaxial lighting

Bright chrome can create glare under ring or coaxial illumination. The low-reflective CrOx / Cr / CrOx coating has three layers: chromium oxide, chromium and chromium oxide. Specify wavelength, measurement side and illumination geometry when agreeing reflectance and optical density; the quoted coating values are not universal across visible and NIR wavelengths.

Auxiliary micro-features on the same plate

Besides the ArUco blocks, auxiliary fiducials such as 10 μm micro-dot arrays, vernier alignment scales or sub-millimetre sub-grids can be patterned on the same glass substrate when the drawing requires multi-resolution or laser-scanner calibration features.

Technical specifications and custom options

Plates can be fabricated from 5 × 5 mm up to 14 inches (355 × 355 mm). The columns below are process grades and material options, not one combined guarantee for every board. Attach each value to the selected substrate, coating, size and inspection method.

Technical specifications and custom options
ParameterStandard production specHigh-precision / custom option
Substrate materialsUltra-clear soda-lime glass, Schott B270, H-K9L, or N-BK7, as agreed on the drawingFused silica (JGS1 or Corning 7980) for the low-expansion option; the 0.55 × 10⁻⁶/K CTE is a fused-silica material property, not a plate-level guarantee for every substrate. Matte opal glass is available for front-lit diffuse reflection.
Substrate dimensionsFrom 5 × 5 mm micro-endoscope reticles up to 14-inch (355 × 355 mm) large-format platesCustom rectangular, circular or stepped outlines; thickness from 0.5 mm to 6.0 mm
Surface flatness≤ 2λ to 5λ per 25 mm on polished float / ultra-clear material, as specified1λ to λ/4 via 6B double-sided planetary polishing, when that grade is specified
Patterning methodDirect laser lithography for masters, or vacuum contact exposure for batch copiesA sub-micron master mask plus contact transfer for multi-unit production after the master is approved
Feature and pitch accuracyStandard production centre-to-centre pitch: ±1.5 μm to ±3.0 μmMaster-mask grade: ±0.5 μm to ±1.0 μm. Minimum feature size down to 0.8 μm to 2.0 μm, reviewed with the artwork. These process grades are not a single series guarantee.
Corner radius (Rmax)Rmax ≤ 1.5 μm at checkerboard intersections, inspected at 500× under an Olympus BX51 DIC microscopeA sharper saddle-point radius down to 1.0 μm may be reviewed for a defined process route. It is not a default guarantee for every plate.
Coating optionsLow-reflective dark chrome (CrOx + Cr + CrOx): R < 10%, and typically R ≤ 8% to 10%, with OD ≥ 3.0, or OD ≥ 3.0 to 4.0, for the specified low-reflective stackBright chrome (R ≈ 60%, OD ≥ 4.0) for UV contact masters or transmissive back-lit setups. Coating values belong to the selected stack, not to every finish.

Selecting illumination and substrate

The usable contrast depends on the light path as much as on the chrome pattern. Choose the substrate and backing with the intended illumination, then confirm the coating stack on the drawing.

1Back-lit (transmissive) setups

Choose clear optical glass — ultra-clear soda-lime, B270 or fused silica — with low-reflective chrome on the top surface, and pair it with a uniform LED backlight diffuser. This arrangement is intended to give high edge contrast for telecentric lenses and microscope objectives.

2Front-lit (reflective) multi-camera rigs

Transparent glass does not provide a white field under front lighting unless it is backed or replaced by a diffuser. Two shop configurations are available: low-reflective chrome patterned on polished white opal glass, giving Lambertian diffuse white squares and low-glare dark squares; or chrome on clear glass with a cured optical-grade white diffuse backing paint or an anodized aluminium mounting frame.

3Master photomask and contact copies

If a production line needs 10, 50 or 100 identical large-format ChArUco plates up to 14 inches, writing every plate by direct laser lithography is slow and costly. A single high-precision ChArUco master photomask can be laser-written, then batch copies produced by vacuum contact photolithography so the approved geometry is repeated at a lower per-unit cost.

Inspection and what to send

High-requirement parts can be polished on a 6B double-sided planetary polisher with cerium oxide to control thickness tolerance and flatness, down to λ/4 when that grade is specified. After development (ADI) and after etch (AEI), batches are sampled at 500× on an Olympus BX51 microscope with a DIC module to inspect checkerboard intersections and micron-scale features for pinholes, burrs and linewidth uniformity.

A target measurement record is separate from the accuracy of an installed camera system.

Discuss your ChArUco target
  • Board dimensions and glass thickness: up to 14 inches (355 × 355 mm), thickness from 0.5 mm to 6.0 mm.
  • Grid layout: number of squares (X × Y), checkerboard square size (mm) and ArUco marker size (mm).
  • ArUco dictionary, for example DICT_4X4_50 or DICT_5X5_1000, or the generated SVG, PDF or CAD file.
  • Coating and illumination mode: transmissive (clear glass) or reflective (opal glass or white backing), and bright or low-reflective chrome.
  • Quantity: a single prototype or a master plus contact-copy batch. Native CAD (DXF, DWG, GDSII, Gerber) is accepted, or the lithography vector file can be generated from the stated OpenCV parameters.

Common questions

How is a ChArUco board different from an OpenCV chessboard?

A conventional chessboard supplies inner corners but does not carry coded markers. A ChArUco board places unique ArUco markers in the white squares so compatible software can identify visible corners when the plate is only partly in the image. The two layouts are different products and are not interchangeable without a matching detector, dictionary and board definition.

Does TL OPTIK certify OpenCV or HALCON compatibility?

No. Boards can be manufactured to match a stated OpenCV or HALCON workflow, dictionary, pattern geometry and software settings. That is pattern and workflow matching, not a software certification or a claim that the board works with every version or every readhead.

Is a 1.0 μm corner radius guaranteed on every plate?

No. The standard intersection acceptance listed here is Rmax ≤ 1.5 μm, inspected at 500×. A sharper radius down to 1.0 μm may be reviewed for a defined lithography route. Grid pitch also has separate standard and master-mask grades.

Does “70% outside the field of view” describe a system performance guarantee?

No. It explains how a compatible vision algorithm can still identify visible corners when much of the board is clipped or blocked. TL OPTIK supplies the patterned optical component, not a complete camera-calibration system, encoder or readhead. The result still depends on the camera, lens, lighting, pose set and software.

Are the dimensions printed on the product photograph a standard size?

No. The photograph shows an example configuration: overall size 270 × 165 mm, 12 × 12 mm checkers and a 5 × 5 dictionary. Other outlines, pitches and dictionaries are made to the approved drawing, from 5 × 5 mm up to 14 inches.

Search