Minimum Limit Line
The lower permitted boundary derived from the controlled drawing or tolerance condition.
Drawing-defined glass reticles and tolerance overlays for visual pass/fail inspection using minimum limits, maximum limits and acceptance zones.
TL OPTIK manufactures custom glass Go / No-Go reticles and tolerance overlay charts that translate drawing-defined limits into visible optical references. They support rapid visual screening of a projected or observed part profile.
The product is defined by the inspection function, not by one universal mounting position. It can be configured as a screen overlay, an internal reticle or another drawing-defined optical component.

A Go / No-Go pattern is not a numerical readout. It places the observed contour against controlled visual limits at the specified scale and alignment.
The example profile remains between the two drawing-defined boundaries.
Concept only — not a measurement result or stock tolerance.
Magnification, focus, distortion, alignment, illumination and the operator method all affect the installed comparison. The glass pattern is one controlled component within that measurement process.
For this reason, the drawing must identify where the pattern sits, which dimensions are scaled and how the operator aligns the observed profile.
Each visual element has a separate role. Combining them correctly is more important than simply adding more lines.
The lower permitted boundary derived from the controlled drawing or tolerance condition.
The upper permitted boundary used to identify an oversize or out-of-profile condition.
The region between agreed limits, interpreted using the defined viewing and alignment method.
A datum for alignment and orientation; it does not represent a tolerance limit by itself.
Nominal profile, upper and lower limits, reference datums, line width and the current drawing revision.
Instrument position, magnification, field of view and whether dimensions refer to the workpiece or image plane.
Critical dimensions, pattern position, orientation, visible-defect limits and the required inspection or calibration record.
Final values and tolerances follow the approved drawing and agreed inspection method.
A part profile alone is not enough. The same tolerance shape can require different glass geometry when the magnification, viewing position or mounting arrangement changes.
Discuss your tolerance reticleTL OPTIK can inspect the agreed glass geometry and pattern against the approved drawing. Traceable calibration, certified gauge status and installed instrument performance require a separately defined scope.
Screen overlays or matched glass references for rapid profile acceptance checks.
Instrument-plane limit references when the optical design and scale relationship are defined.
Drawing-defined pass/fail patterns integrated into an OEM visual inspection workflow.
It is a drawing-defined optical comparison component that shows acceptance limits for a projected or observed workpiece profile. The operator uses the boundaries to make a visual pass/fail decision under the specified optical conditions.
No. A Go / No-Go reticle is defined by its tolerance-screening function and may be used in different optical positions. An optical comparator glass chart is a broader screen-plane chart product that can carry radius, angle, grid, thread, gear or other comparison patterns.
Not by default. It is supplied as a drawing-defined visual comparison component. Traceable calibration, certified gauge status or complete measurement-system verification must be agreed separately before quotation.
Provide the nominal profile, minimum and maximum limits, reference datums, instrument or viewing location, magnification, workpiece-side or image-side dimensions, orientation, mounting geometry and required inspection record.
A reference sample or clear image can support the review, but an approved drawing is still needed to define the production geometry, orientation, critical limits and acceptance method. Instrument model information alone is not sufficient.
Yes, when the profiles, labels, scale correspondence and selection method remain unambiguous in the intended field of view. The layout must be reviewed with the instrument and operator workflow.