Custom Optical Comparator Glass Charts & Reticles

Custom glass charts for optical comparators and profile projectors. Radius, angle, grid and profile patterns made to specified magnification and mounting dimensions.

Compare at the screen

TL OPTIK manufactures custom patterned glass charts for optical comparators and profile projectors. Used at the instrument’s viewing screen, these charts provide reference lines, radius arcs, angle graduations, grids or specified profiles for comparison with a projected workpiece image.

Chart geometry, markings and mounting dimensions are defined around the instrument configuration, intended projection magnification and inspection task. Chromium patterns are formed on glass by precision photolithography according to the approved drawing.

Circular optical comparator glass chart with radial lines and concentric reference arcs
Profile projector viewing screen with comparison chart in an inspection workshop
Application reference: comparison charts used at a profile projector viewing screen.

A reference for the projected image

The instrument enlarges a workpiece edge or surface feature onto its viewing screen. The operator aligns the projected image with chart lines, arcs or profiles to compare dimensions, radii, angles and shape.

An optical comparator overlay is used over an existing screen. Patterned glass for a replacement screen assembly also needs the original screen-surface and mounting specifications. A transparent glass chart does not by itself provide a diffusing projection surface.

Choose by the comparison task

Use the chart name to identify the task, then define its actual geometry and scale. Toolroom charts can combine radius, angle and grid references on one glass plate.

Centerline screens

Horizontal, vertical and crosshair references for centring and alignment. Define the intersection position and mounting direction.

Radius charts

Compare projected arcs with specified radii. Label the radius series and the magnification used to interpret it.

Angle charts

Protractor charts compare edge directions and included angles. Define the angular range, divisions and zero axis.

Concentric circle charts

Compare diameters, concentricity and visible profile deviations. Formal roundness assessment needs an agreed measurement method.

Grid overlay charts

X/Y references for positions and spacing. Specify the relationship between grid pitch and workpiece dimensions.

Thread profile charts

Compare the specified thread profile. Supply the thread form, pitch, projection direction and applicable standard.

Gear profile charts

Compare the specified tooth section using approved profile data and projection conditions.

Custom profile overlays

Part outlines and agreed tolerance boundaries tied to the drawing revision, reference datums and magnification.

Pattern concepts only, not to scale. Thread and gear drawings illustrate chart types, not a specified standard profile.

Match the projection scale

Linear, diameter, radius and profile charts map workpiece dimensions onto the screen at a specified magnification. State whether chart labels show the workpiece value or the physical screen dimension.

A dimensional example

At 10× magnification, a 1 mm workpiece feature projects to 10 mm on the screen.

Illustrative geometry only. These examples are not a list of stock chart specifications or an instrument calibration.

Keep angle and line width distinct

Ideal uniform magnification preserves angles, but angular comparison still requires correct alignment and consideration of instrument distortion. A dimensional chart cannot be transferred between magnifications without reviewing its scale.

Choose line width for readable contrast and reliable edge comparison. Enlarging every feature of a small crosshair reticle by the same factor does not automatically produce a suitable screen chart.

Technical configuration

Final values, tolerances and inspection methods follow the approved drawing. Confirm the viewing screen and chart as a matched assembly.

Product form
Glass overlay chart; patterned glass for replacement screen assemblies subject to instrument review
Glass material
Selected for the optical, mechanical and processing requirements
Outline and thickness
Circular or custom outline, thickness and edge finish to drawing
Usable pattern area
Defined by the viewing area, mounting clearance and edge exclusions
Chart geometry
Centerlines, radius arcs, angular graduations, grids, specified profiles or combined layouts
Projection magnification
Specified for each dimensional pattern; identify each scale in a multi-magnification chart
Units and markings
Metric, imperial, angular or custom labels; state whether values refer to the workpiece or screen
Pattern process
Chromium patterns on glass formed by precision photolithography
Line width and tolerances
Agreed for readability, pattern geometry and the inspection method
Pattern face and orientation
Identify the viewing side, film side, reading direction and mounting datums
Screen interface
Match the holder, outside dimensions and any required screen-surface treatment
Inspection records
Drawing-based dimensional and pattern inspection as agreed; calibration scope reviewed separately

Define the chart with your instrument

For optical comparator and profile projector manufacturers, metrology equipment suppliers and inspection laboratories. Send the information that controls the screen fit and comparison method.

Discuss your glass chart
  • Instrument make, model and intended chart location
  • Screen diameter, glass outline, thickness and mounting drawing
  • Projection magnification and whether labels represent screen or workpiece dimensions
  • Chart type, artwork, scale units, line width and drawing revision
  • Viewing direction, pattern face and alignment datums
  • Quantity, inspection criteria and any calibration or report requirements

Chart inspection and system calibration

Inspect agreed line widths, feature dimensions, scale spacing, centre position, orientation and visible defects against the approved drawing. Chart geometry inspection is separate from instrument calibration. Magnification, distortion, alignment, focus and the operator’s method contribute to the installed measurement result.

Quality, Inspection & Delivery

Common questions

Is this an eyepiece reticle?

This product is intended for the viewing-screen area of an optical comparator or profile projector. A measuring microscope reticle or eyepiece graticule uses a different mounting and optical arrangement. Specify the actual location of the component before ordering.

Can one chart cover several magnifications?

Dimensional, radius and profile patterns must match the intended projection magnification. Several labelled scales can share a chart, provided their correspondence is unambiguous. Angular references are unchanged by ideal uniform scaling, but alignment and instrument distortion still matter.

Can clear glass replace the projection screen?

Not on diameter alone. An overlay sits over an existing viewing screen; a replacement screen may also require an image-forming or diffusing surface and a particular mounting construction. Review the original screen specification before defining a glass comparator screen.

Can you work from an existing chart?

A drawing, reference sample or clear image can support the review. Confirm dimensions, artwork, intended magnification, mounting references and acceptance criteria before manufacturing. Brand and model information alone does not establish compatibility.

What inspection documents are available?

Dimensional and pattern inspection records are defined with the order. If traceable calibration, a specified standard or a third-party certificate is required, agree the scope and feasibility before quotation. Component inspection does not certify the complete instrument.

Search